How do you light the pilot light on a gas log?

How do you light a gas log safety pilot? You turn the control knob to the pilot position, push the knob in, light the pilot with a match, then hold the knob down for 30 seconds or so until the pilot stays lit by itself. Once the pilot light will stay lit on its own, you can then move the knob to the “On” position.

Accordingly, how do you light the pilot on a gas fireplace Ignitor?

Lighting Instructions:

  1. Turn the gas knob clockwise to the off position.
  2. Wait five (5) minutes to clear out any gas.
  3. Find pilot located in front of back log.
  4. Turn gas knob counter-clockwise to pilot.
  5. Depress slightly and hold gas knob while lighting the pilot with the push button igniter.

Likewise, is it OK to leave the pilot light on in a gas fireplace? Leaving the gas on keeps this compound moving out of the tubes. Keeping the pilot light on will also keep moisture out of the unit and in turn, help prevent corrosion. As you can see, it’s probably best in most cases to extinguish the pilot light in your gas fireplace during the months when you don’t need heat.

Similarly, it is asked, is it OK to leave gas fireplace on overnight?

It usually runs all night. However, unvented gas fireplaces (aka vent free, ventless) can adversely affect indoor air quality and shouldn’t be used more than a few hours at In most cases, if your fireplace was installed properly, you can leave it on indefinitely.

How do you turn on a gas fireplace without the key?

When learning how to turn on a gas fireplace without a key, confirm that the unit has a control panel with an igniter switch. Remove any fireplace decoration that’s in the way. Control panels can usually be found at or around the base of the fireplace, concealed by a decorative screen that should be moved.

10 Related Question Answers Found

Why is my gas fireplace not turning on?

1. Pilot light systems are the most common reason gas fireplaces fail to light, so check the main gas valve to make sure the gas is turned on. If gas is coming out of the pilot, but it still won’t light, the spark igniter could be the problem. Look for and clear out any debris between the igniter and thermocouple.

How do you turn on gas logs?

How do you light a gas log safety pilot? You turn the control knob to the pilot position, push the knob in, light the pilot with a match, then hold the knob down for 30 seconds or so until the pilot stays lit by itself. Once the pilot light will stay lit on its own, you can then move the knob to the “On” position.

How do you know if you have a bad thermocouple?

If you can’t get the flame to light at all, and you’re sure the gas is on, there’s probably an obstruction in the pilot tube. If the flame lights and goes out when you release the gas control knob after holding it in for the recommended 20 to 30 seconds, that’s the sign of a thermocouple malfunction.

Are gas fireplaces safe?

Gas fireplaces are safe. But as with all gas appliances, they do produce carbon monoxide. If something goes wrong, carbon monoxide put the home’s occupants at risk. Therefore, carbon monoxide detectors are a critical part of gas fireplace safety, even if you don’t use the fireplace often.

What does a thermocouple look like?

The thermocouple looks like a piece of metal tubing smaller than a soda straw. To find it, first locate the gas control box. This is the box that the main gas line enters, where you turn the gas on in the furnace. The other end of the thermocouple sits in the flame of the pilot light.

Where is the pilot light adjustment screw?

The pilot adjustment screw is located on the gas valve, just “above” the pilot tube (See Figure 3). Remove the cap screw and find the actual adjustment screw behind it. Turn the screw in to decrease pilot flame, out to increase.

How do you test a thermocouple?

Steps Locate the pilot light controls on the gas valve. Turn the pilot light on for 30 seconds. Release the button to see if the pilot light goes out. Turn off the gas supply to test the thermocouple again. Count to 20 and wait for the pilot light to go out. Listen for clicking near the gas valve.

Can a pilot light flame be adjusted?

Adjusting the Pilot Flame If the pilot flame is too small, you may be able to make it larger by turning the pilot adjustment screw on the valve control counterclockwise with a screwdriver to open it. The cause of a weak flame may also be an obstruction in the pilot tube.

Can you clean a thermocouple?

If the Thermocouple is faulty it will cause the unit to shut down. How to clean? Remove Thermocouple from pilot assembly, using steel wool or emery cloth to lightly clean the tip removing any soot or build up that might have accorded due to an improper pilot flame.

Why does gas fire cut out?

An oxypilot is an atmospheric sensing device in place to put out the gas fire if there is insufficient oxygen in the room. If the oxypilot becomes blocked with dust or soot, the flame lifts away from the thermocouple or flame sensing electrode. This will make the fire cut out, or pilot not light.

Leave a Comment