A boiler that keeps losing pressure is therefore always cause for concern. There are two main problems that typically cause a loss of pressure – water escaping somewhere in the system or a failure of the expansion valve and resulting damage to the pressure relief valve.

Keeping this in consideration, why does my boiler keep losing water pressure?

Your combi boiler can be losing pressure for a number of reasons. Pressure loss may be caused from a leak in the pressure relief valve, an issue in the expansion vessel, air in your system, or a leak in the heating pipework itself.

Secondly, is low boiler pressure dangerous? The good news is that low boiler pressure is nothing to panic about and is not likely to cause any damage to your boiler. On the other hand, it can have a real effect on the efficiency and effectiveness of your heating system, making it hard to keep your house warm and costing you more on your energy bills.

Also question is, why does my boiler keep going off?

Lack of water flow If the boiler keeps shutting off, it could be due to closed valves, air caught in the system or a broken pump. If there is enough air in the system to cause your boiler to switch itself off, it should be obvious when you start bleeding your radiators, as plenty of air will gush out of them.

How often should a combi boiler lose pressure?

If the pressure has fallen to below 0.5 bar (often indicated by a red section), then it shows that some water has been lost out of the system and it must be replaced. The pressure in a central heating system will usually need to be topped up only once or twice a year.

13 Related Question Answers Found

How do I find a leak in my boiler?

Place a sheet of colored paper under the boiler – if any drops appear on the paper, it should make it very easy to find the leak in your central heating system. Follow the wet spots up along the central heating system and see if you can spot where the water is coming from.

Can a boiler lose pressure without a leak?

Note, however, that even if the pipework is wet to the touch, this does not necessarily indicate that there is a leak – it may be caused by condensation due to temperature differences. If your boiler continues losing pressure and there is no leak, then there may be a fault with the boiler.

How often should you need to top up boiler pressure?

Topping up once or twice a year is normal, but it will dilute the corrosion inhibitor, so maybe add some every five years.

Can a leaking tap cause boiler pressure to drop?

What causes a drop in pressure? You may have a leak somewhere in your boiler system. It may only be a tiny leak but, if it’s gone unnoticed for some time, it could lead to a gradual drop in pressure. Take a look around your home for signs of damp patches, around pipes, radiators and the boiler itself.

Can a boiler explode?

While historically, boilers would over-pressurise and explode with alarming regularity, modern boilers are manufactured to be able to withstand excessive pressure, and can typically handle an operating pressure of 20 PSI. When pressures increase beyond this level, the boiler can fail, which can lead to an explosion.

Where is pressure relief valve located?

Where is the Water Heater Pressure Relief Valve? The T&P valve is usually located high on the side or on top of the tank. It’s connected to a pipe that runs down the length of the water heater and stops a few inches above the floor.

How can I find a leak in my house?

Use your water meter to check for leaks Make sure no water is being used inside or outside of your house. Locate your water meter and check the leak indicator to see if it is moving. Or, you can also take a meter reading and wait 1 or 2 hours and take another meter reading (make sure no water is used during this time).

How do I stop my boiler from short cycling?

In a fully automatic central heating system the short cycling of the boiler can be prevented by using the room thermostat/programmer and hot water cylinder thermostat to switch on the electrical supply to the boiler.

How do I check my boiler pressure?

To check your boiler’s pressure, you need to locate the pressure gauge on your boiler. If there is the correct amount of pressure in your system, the needle should be between 1 and 2 bar. This area is usually designated in green. Below 1 and greater than 2 is in red, indicating critical zones.

How do I reset my Worcester boiler?

To reset the boiler: ? Turn the Central heating temperature knob anticlockwise to the “RESET” position and hold for approximately five seconds and then turn the knob back to the original temperature setting.

What is boiler short cycling?

Boiler “short cycling” occurs when an oversized boiler quickly satisfies process or space heating demands, and then shuts down until heat is again required. A boiler cycle consists of a firing interval, a post-purge, an idle period, a pre- purge, and a return to firing.

Why does my Worcester boiler keep needing to be reset?

Some of the most common boiler faults which could be triggering the need to reset it frequently include: A leak in the heating system. A blocked plate heat exchanger. An electrical part is faulty and needs replacing.

How do you know if your boiler is overheating?

A build-up of limescale, sludge and other debris in the central heating system can be detected before the boiler will begin to overheat. If you’ve noticed that any strange sounds from your central heating system or that any radiators haven’t been heating up properly, then they’re strong indications of a blockage.