Can you use regular stove pipe on a pellet stove?

Never use “regular” single wall or double wall stove pipe for pellet stoves or inserts. Burning pellets causes a more corrosive environment and “regular” stove pipe will not last.

Then, do you need double wall pipe for a pellet stove?

A pellet stove requires outdoor venting through a pipe. This can be chimney pipe as long as it meets certain requirements. The pipe must be double-walled, with an inner lining of stainless steel. It must also be sealed at the joints so that carbon monoxide and other exhaust cannot leak into the home.

Also Know, how far can you run pellet stove pipe? Most pellet stoves have a 3-inch vent pipe at the exhaust of the unit. If this exhaust will be run more than 15 feet (right angle elbows count as 5 feet), then the exhaust should be run through 4-inch pipe.

Herein, what kind of chimney do I need for a pellet stove?

No, you do not need a traditional stone or brick chimney in order to install a pellet stove in your home. With that said, pellet stoves do require specific venting. To learn more about the code requirements for your area, contact your nearest authorized Harman dealer.

What type of stove pipe do I need?

Standard Single. Single-wall stove pipe is used on standard wood stove installations. It should be at least 24-gauge sheet metal or thicker — the lower the gauge, the thicker the metal. Typical code requires that single-wall stove pipe maintain at least an 18-inch clearance from any combustible material.

14 Related Question Answers Found

Do I need to line my chimney for a pellet stove?

Yes, your pellet stove can be vented through your existing chimney, providing your pellet stove is placed in front of your existing fireplace and you have the proper clearance, the airspace between the stove, the walls and you meet the minimums as defined in the owner’s manual.

Do I need single or double wall stove pipe?

Single wall black stove pipe needs to be at least 18″ from combustibles, will radiate more heat than double wall black stove pipe (desirable in most cases), costs way less, and can be cut to length if needed. Double wall black stove pipe has a 6″ from combustibles and isn’t very hot to the touch.

How hot does double wall stove pipe get?

These pipes only need a 2-inch clearance to combustibles because they remain cool on the outside, while their internal design allows them to withstand temperatures as high as 1,700 or 2,100 degrees Fahrenheit for a limited time.

Can you run pellet stove pipe horizontal?

Horizontal Venting For A Pellet Stove. Horizontal venting is the simplest and cheapest way to remove the exhaust gases from your pellet stove. The vent pipe is connected to an adapter at the back of the stove, then run out through the wall adapter plate to a distance of at least six inches from the exterior wall.

What’s the trick to putting stove pipe together?

Putting Together a Stove Pipe Seam Set a length of stove pipe flat on the floor with the two open ends of the center seam facing away from the floor. Push the two sides of the seam together. Push down and in on both sides of the stove pipe seam until you hear a loud snap.

How long does double wall stove pipe last?

Double Wall Stove Pipe was designed to work with your Stainless Steel Chimney to form a complete Wood Stove Venting system! * If a wood burning appliance is used every day in the heating season, surveys have shown that a single wall stove pipe will need replacement every two or three years.

Which direction does stove pipe go?

Assuming a drawing wood stove or wood boiler, the correct way is with the crimped end down. As the chmney cools it will condense some moisture, and if you assemble the other way your joints will leak black goo out each joint, even if you are so perfect you don’t think you will ever make any creosote.

Can a pellet stove be vented through the roof?

For instance, wood-burning stoves will always be vented through the roof of your house, but pellet-burning stoves can be vented vertically through the roof, or horizontally through the wall to the outdoors. Same with gas stoves – venting can be routed in either direction – vertically or horizontally.

Is it safe to run a pellet stove overnight?

American Energy Systems pellet stoves and fireplaces are designed to provide safe, consistent heat with minimal work. That means that you can start your stove and safely leave it unattended overnight, while you run for groceries, or meet friends for dinner.

How long will a 40 lb bag of wood pellets burn?

24 hours

Can you run a pellet stove without electricity?

Pellet stoves require a source of electricity in order to operate. Without an alternative source of power, the stove will be unable to turn on or ignite.

Does a pellet stove use a lot of electricity?

The average home uses about 7.3 tons of pellet fuel or 6.5 cords of wood per season. You should also note that most pellet stoves have fans, controls and fuel-feeder systems that run on electricity; the monthly electric bill for a typical stove is about $9.

Can you install a pellet stove without a chimney?

It is true, a pellet stove can still work even without the flue, because it works with forced ventilation.

Can a pellet stove be direct vented?

Pellet Stoves – most are vented horizontally directly through the wall to the outdoors, similar to direct vent gas fireplaces. Fireplace Inserts – most are vented vertically through the roof via the existing chimney.